BONA-GM-T05-Pilot-Scale TFF Ultrafiltration System

BONA-GM-T05 pilot-scale tangential flow ultrafiltration system: 300 mL minimum working volume, 0.5 m² membrane area, 5 L jacketed material tank. Manual crossflow UF for process development and pilot bioproduction. BonaTech.

  • Minimum Operating Volume300 mL
  • Effective Filtration Area0.5 m²
  • Operating Temperature5-55 °C
  • pH Range2-12
  • Jacketed Material Tank5 L (sealed)
  • Flow Rate0.1-10 L/h

Product Overview

Peristaltic Pump with Stepless Speed Control, Low-Shear Transfer

A peristaltic pump is used, with stepless speed regulation and a flow rate of 0.4-13 LPM; its low shear force is friendly to proteins and other bioactive substances. The filtration rate is 0.5-10 L/h (depending on the material and membrane cassette).

Process Volume 1-100 L, Adjustable Number of Membrane Cassettes

The equipment process volume is 1-100 L, with a minimum operating volume of 300 mL. The UF membrane cassette holder is made of SUS316L stainless steel, electropolished, with all sanitary connections; depending on throughput requirements, it can accommodate 1-5 membrane cassettes, and can also be retrofitted with other models of microfiltration and ultrafiltration membrane cassettes.

Sanitary-Grade Membrane Cassette, Accurate Retention and Low Adsorption

Equipped with a 0.5 m² membrane cassette, complying with U.S. FDA, USDA, and 3-A sanitary standards. The UF membrane cassette is made of polyethersulfone (PES) and modified cellulose using defect-free casting technology, with accurate retention, high flux, low protein adsorption, and long service life.

Parameters Directly Transferable to Industrial Production

The holder is designed based on hydrodynamics to fully ensure membrane surface cross-flow velocity and guarantee stable and reliable test data. The pump flow range is configured strictly according to the membrane surface velocity of sanitary-grade membrane elements, so the parameters obtained from experiments can be directly transferred to industrial production.

SUS316L Sanitary-Grade Piping with Excellent Welding Quality

All piping is made of SUS316L stainless steel with electropolished surfaces and sanitary connections, joined with silicone tubing. All stainless steel welding uses automatic argon shielding, single-side welding with double-side forming; pipelines are connected by ferrule and tri-clamp, ensuring pressure and corrosion resistance and meeting sanitary standards.

Manual Local Control, Simple and Safe Operation

The system adopts a manual local control operation mode: the recirculation port is equipped with a sanitary diaphragm valve to adjust operating pressure, the inlet with a sanitary butterfly valve for system isolation, and two diaphragm pressure gauges provide real-time monitoring. The material tank is 5 L and can be temperature-controlled via chilled water / hot water.

Standard Configuration

One peristaltic pump (1 unit)
one SUS316L stainless steel membrane holder (1 unit)
one membrane cassette (1 unit)
two pressure gauges (2 sets)
one material tank (1 unit)
one pressure regulating valve (1 unit)
equipment support frame
connecting clamps
piping and fittings (several)

Technical Specifications

Recommended Models

Typical Applications

Tangential Flow Filtration (TFF) achieves separation by flowing the feed tangentially across the membrane surface. Compared with dead-end filtration, it better suppresses membrane fouling and maintains stable flux, and is widely used for clarification, concentration, purification, desalting, and buffer exchange of biomacromolecules. Typical application directions are listed below:

01

Clarification Filtration of Biological Samples

Used for clarifying cells, cell debris, microbial lysates, and TCM aqueous extracts, effectively removing impurities to ensure the smooth progress of downstream biological processes such as protein salting-out.

02

Protein and Antibody Concentration and Purification

For biomacromolecules such as albumin, recombinant proteins, antibodies, ADC drugs, and coagulation factors, the tangential-flow ultrafiltration system provides efficient concentration solutions, while also suitable for the separation and enrichment of viruses, microspheres, cell supernatants, and nanoparticles.

03

Desalting and Buffer Exchange for Macromolecule Drugs

In the preparation of biological products such as nucleic acids, peptides, insulin, interferon, and growth hormone, Tangential Flow Filtration enables rapid desalting and impurity removal, meeting the high-purity requirements of materials such as chondroitin sulfate.

04

Buffer Exchange and Exosome Processing

The tangential flow system efficiently performs buffer exchange for viruses, plasmids, oligonucleotides, and lipid nanoparticles; it is especially suitable for the gentle separation and system conversion of sensitive materials such as exosomes, hyaluronic acid, and sodium heparin.

05

Pyrogen Removal for Injection-Grade Drugs

For injectable APIs, biomacromolecule drugs, TCM injections, and pharmaceutical excipients, the tangential flow system provides professional pyrogen removal, ensuring process water and buffers meet stringent pharmacopeia standards.

06

Separation and Purification for Vaccines and Gene Therapy

In vaccine R&D and genetic engineering, the Tangential Flow Filtration system provides one-stop tangential-flow process support — from cell harvest to concentration and purification — for viral vectors, nucleic acid drugs, and recombinant proteins.

Get a Custom Solution & Quote for BONA-GM-T05