Pure water (RO permeate) is primary-purified by reverse osmosis, removing 96–99% of ions — suitable for glassware rinsing, general physical/chemical tests and instrument feed water. Ultrapure water adds UV oxidation, pyrogen-removal UF and terminal microfiltration, reaching 18.25 MΩ·cm (25 °C), TOC <3 ppb and bacteria <1 cfu/mL — suitable for HPLC / mass-spec analysis, molecular biology and cell culture. Our system delivers both from one unit, on demand.
Resistivity reflects residual ions in water; 18.25 MΩ·cm (25 °C) is the theoretical limit of pure water — near-zero ion content. Ultrapure water readily absorbs CO₂ from air and leaches contaminants from containers, so resistivity falls quickly with standing time. Draw and use it immediately; the system's online resistivity monitor reflects water status in real time.
Dual output means one unit provides two independent streams: RO permeate (pure water) and deeply purified ultrapure water (via UV oxidation, pyrogen-removal UF and terminal MF), each with its own tap and drawable simultaneously. Rated production is 30 L/h, with instantaneous draw of 1.5–2 L/min at full tank — meeting multi-point lab demand.
Yes. The front end uses two-stage pretreatment — softening and silica-removal cartridges — delivering water at hardness ≤0.03 mmol/L and soluble silica ≤0.01 ppm before RO, protecting water quality while extending RO-membrane and downstream consumable life. In regions with especially poor source water, pretreatment can be upgraded.
TOC (total organic carbon) affects the baseline/background of high-sensitivity analyses such as HPLC and mass spec. Pyrogen (endotoxin) affects cell culture, animal studies and injectable-related research. RNase/DNase residues degrade RNA/DNA samples and are key controls in molecular biology (PCR, sequencing, nucleic-acid extraction). Our ultrapure water reaches TOC <3 ppb, pyrogen <0.001 EU/mL, RNase <1 pg/mL and DNase <5 pg/mL — covering the above scenarios.
Daily upkeep is simple: the system monitors resistivity and TOC online, so consumable status is clear at a glance. Softening cartridges, silica-removal cartridges, the RO membrane, UV lamp, UF module and terminal microfilter are all modular, plug-in replacements requiring no special tools; replacement interval depends on source water and usage — replace when due or when indicators are abnormal. BonaTech provides long-term consumable supply and periodic inspection.
In normal flow filtration (NFF, also called dead-end filtration), the feed passes perpendicular to the membrane, so foulants deposit on the surface and cause rapid flux decline and membrane blinding — best for single-pass clarification of low-solids streams. In TFF, the feed flows tangentially (parallel) to the membrane, continuously sweeping the surface to limit concentration polarization and fouling, allowing extended runtime. TFF is the preferred mode for concentrating and diafiltering high-solids, high-viscosity or high-value feeds — particularly for UF concentration, buffer exchange (diafiltration) or processing feed with significant solids load.
Cassette (flat-sheet) modules provide high packing density and low membrane-replacement cost, with retention ratings spanning MF (0.05–0.45 µm), UF (1K–800K Da MWCO) and NF (200–800 Da), in materials including PES, regenerated cellulose, PVDF, composite and polyamide. Hollow-fiber modules are self-supporting with open lumens that tolerate high solids and viscosity and are easy to clean (CIP-friendly), covering MF (0.1–0.65 µm) and UF (1K–750K Da MWCO). Selection depends on feed characteristics and process objectives — our application engineers can help specify the optimal configuration.
Base the choice on the molecular-weight separation margin between the target and impurities: use MF to remove cells and particulates; use a UF membrane with an MWCO roughly one-third to one-fifth of the target molecule molecular weight to concentrate proteins or virus-like particles (VLPs); use NF or cascade diafiltration to remove salts and small molecules. If uncertain, send a sample for a bench-scale feasibility study — we will specify the membrane based on measured flux and sieving/rejection data.
The bench-top system is a compact, manually controlled unit holding 1–5 cassettes, with a minimum working volume (MWV) of 50–300 mL — ideal for lab trials and process development. The fully automated system uses PLC control with pre-programmed concentration, DF, CIP and calibration recipes, closed-loop control driven by real-time TMP and flux-decay monitoring, and multi-level user access with an audit trail — suited to pilot and production. Both share identical process parameters, enabling seamless scale-up.
During concentration, the feed recirculates in a closed loop while permeate is continuously removed, reducing volume and raising product concentration. During diafiltration (DF), buffer is added to the retentate while permeate is removed synchronously, exchanging salts and small-molecule impurities. The system operates at ambient temperature with low shear; DF recovery can reach ≥95% with full bioactivity retention of the target.
Yes. Both cassette and hollow-fiber modules are reusable. Automated systems include an inline CIP (clean-in-place) recipe with dedicated cleaning agents to remove fouling from proteins, organics or inorganic scale; during shutdown, modules are preserved per protocol with storage solution. Single-use configurations are also available, and we supply membrane elements across all retention ratings for the long term.
Exosome sources differ markedly in viscosity, impurity profile and vesicle concentration, so the membrane type, MWCO and purification route must be matched to the source — see the "Process Route Examples" section on our Exosome page. Final selection should weigh feed properties, throughput and purity target. Share your feed information and our engineers will tailor a solution for you.
Our system uses internal-pressure hollow-fiber PES membranes with open channels and a VFD pump for stepless flow control, so shear at the membrane surface is adjustable. We keep shear in the "sufficient but not excessive" range matched to exosomes' shear sensitivity, avoiding vesicle rupture from over-high shear.
Elements can be used alone for single-stage filtration trials, or combined at different cut-offs for two-stage continuous filtration — supporting integrated exosome pre-treatment and UF enrichment, and adaptable to clarification, concentration and buffer-exchange workflows.
Yes. Under the VFD control system, key parameters such as feed flow and membrane-surface shear are continuously adjustable and logged, making them easy to transfer and reproduce across scenarios and batches — providing a consistent technical platform for customizing routes across diverse samples.
Membrane elements use a transparent PMMA housing so fiber status and operation are directly visible at every step — you see and control each stage — backed by real-time monitoring and adjustment of flow, pressure and other key parameters through the control system.
Absolutely. Share your feed info (source, volume, target purity and throughput) and our engineers will help design a bench-trial plan and, based on the trial data, advise on membrane selection and process route.
---
Yes. One host can accept different cut-off elements spanning MF (0.05–0.45 μm), UF (1K–800K Da) and NF (100–800 Da); materials include organic spiral-wound, hollow-fiber and inorganic ceramic membranes, using imported membrane sheets for quick swap with no equipment modification.
Life depends on feed nature and maintenance, typically 1–3 years. Replace when flux keeps dropping and cannot be restored by chemical cleaning, rejection drops markedly, or the fiber/sheet is physically damaged. We provide long-term element supply and condition-assessment service.
Yes. For different foulants — organic, inorganic scaling, biofouling — we supply corresponding inline CIP protocols and dedicated cleaning agents, and the manual gives cleaning formulations and interval recommendations to extend membrane life and stabilize flux.
---
Yes. We support non-standard customization based on material characteristics, throughput and site conditions — skid-mounted, modular, automated-integration, etc. Standard configurations ship in 7–15 business days; custom configurations generally 20–30 business days; complex projects are evaluated case by case.
Standard configurations ship in 7–15 business days; custom configurations in 20–30 business days. The system carries a 1-year warranty with lifetime technical support and membrane-element supply; out-of-warranty paid repair and spare parts are available.
Yes. After delivery we dispatch engineers for on-site installation, piping connection and commissioning, and train your operators and maintenance staff so you can run and maintain the equipment independently and to standard.
---
Equipment features sanitary design (SUS316L wetted parts, tri-clamp connections, mirror polish, CIP/SIP capable), meeting GMP and food-contact sanitary requirements. Key components and the complete system are CE certified, and we can provide material certificates and validation documents (IQ/OQ/PQ) on request.
---
Tell us about your feedstock characteristics and process requirements. A BonaTech engineer will provide one-on-one answers and a tailored solution within 1 business day.